loading

Motortronics™

VMX Synergy


AC Supply Voltage: 110 – 230 Vac

HP Ratings: 10-400 HP

Amp Ratings: 17 to 477 Amps

Overload: Full Motor overload with Memory.

Bypass: Internal

Inputs/ Outputs: 4 x programmable output relays; 3 x programmable digital inputs; Analog input/ outputs; USB for data logging and parameter setting/saving; Thermistor

VMX SYNERGY BROCHURE

VMX Series Compact Soft Starter


AC Supply Voltage: 200 – 600 Vac

HP Ratings: 3 to 1200 HP

Amp Ratings: 18 to 1250 Amps

Overload Rating: 500% for 60 sec.

Enclosure: Available as Module Only or in NEMA 1/12

VMX Brochure

VMX-S Series Configured Soft Starter


AC Supply Voltage
200 to 600 Vac

HP Ratings
5 to 1200 HP

Amp Ratings
18 to 1250 Amps

Overload Rating
500% for 60 sec (1.0 SF)

Enclosure
NEMA 4/12

Bypass
Shunt Rated Contactor

VMX-S Brochure

VMX-H Series Configured Soft Starter


AC Supply Voltage
200 to 600 Vac

HP Ratings
5 to 1000 HP

Amp Ratings
21 to 1080 Amps

Overload Rating
500% for 60 sec (1.15 SF)

Enclosure
NEMA 4/12

Bypass
Line Start Rated Contactor

VMX-H Brochure

MVC4 Series


 

The MVC4 Medium Voltage Series Soft Starter is designed to start AC motors in any fixed speed application. It provides maximum protection with “True Thermal Modeling,” while allowing smooth, stepless control of acceleration and deceleration. The MVC4 Series guarantees power control and protection for your most important assets.

AC Supply Voltage
2300, 3300, 4160, 6000/7200V, 11-15kV
VAC +10% to -15%, 50/60 Hz line voltages

HP Ratings
Up to 10,000HP @ 7.2kV (800 Amps max)
Up to 20,000HP @ 15kV (800 Amps max))

SCR Overload Ratings
500% – 60 seconds, 600% – 30 seconds

Contact factory for higher rating requirements

MVC4 Brochure

Stop AC Motor Loads Quickly and Safely… as easy as A-B-C

Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The ABC Series “automatic braking controller” features full-wave DC braking which can be adjusted to stop your load quickly, repeatably and reliably…even if load conditions change. The ABC Series meets the three main objectives that are important in every industry: Maximized Safety, Increased Productivity and Maintenance-Free Operation.

Maximum Safety

Protect Machinery & Operators The ABC Series is designed to eliminate dangerous coast-to-stop times of rotating machines and equipment. The ABC Series also eliminates the dangerous practice of jamming the machine to bring it to a stop, which can present potential danger to operators and passers-by alike. OSHA and other safety agencies pay close attention to these types of operating conditions and recognize brakes as an important part of a system to guard against potential dangers. The ABC Series is an ideal way to add braking and eliminate dangerous “coast-to-stop” times in your application.

Increased Productivity

Stop AC Motors Quickly for a Profitable Operation Long coast-to-stop times equal lost production time. Now you don’t have to wait forever for the load to come to a stop before you make blade changes or change a tool. Simply stop your equipment using an ABC Series electronic brake for increased efficiency and product through-put. The ABC Series also eliminates any need for “plug reversing.” Reversing a load when it is still spinning creates mechanical shock which can cause equipment breakage and extended downtime. Your machinery can now do what it was designed to do… make product at a profit.

Maintenance Free Operation

Eliminate Costly Down Time Using the ABC Series electronic brake eliminates the wear and tear on mechanical brakes in the system. This means less time and money is spent replacing discs or pads (which is especially important given the “shorter life” material used in today’s mechanical brakes). Let the mechanical brake act as a holding brake and let the ABC Series do the stopping. The ABC Series eliminates the common (and also dangerous) practice of “jamming” equipment to stop the load. Expensive blades and tooling are no longer “sacrificed” to stop your motor. The ABC Series for faster, smoother stopping and maintenance free operation.

Easy to Install

The ABC Series microprocessor insures proper connections and coordinates system operation. Simply wire the ABC Series electronic brake into the motor starter circuit for a cost effective, maintenance-free means of bringing the motor and load to a stop. No isolation contactors, no additional logic wiring…it works right off the motor input leads! It’s as easy as A-B-C.

Easy to Select

The ABC Series units are sized by amperage and should be selected based on the application requirements. “Standard Duty” ratings are sized for 95 – 110% of motor FLA. “Extra Duty” ratings are sized for 150 – 250% of motor FLA. Specify maximum braking current and voltage when ordering.

Electronic Motor Brake Brochure

Keep motors warm and moisture-free during extended shut-down periods

Easy to Install

Whether retrofitting an existing starter or installing a new one, the MWH Series is easy to apply. Just wire it in parallel to the magnetic starter’s line and load connection, connect the necessary auxiliary
contacts and installation is complete.

Simple Adjustment

Output voltage is factory set to maintaina +5° to 10°C differential above ambient temperature. This adjustment can be used to trim the control as required for each application.

Self Protected

In addition to built-in fuse protection, the MWH Series features an RC snubber circuit across the SCR which protects it from any rapid rate of change in the system voltage. A metal oxide varistor (MOV) protects the unit against voltage spikes for reliable, maintenance-free operation.

Fully Automatic Operation

Designed for fully automatic operation, the MWH Series turns on when the motor starter has turned off. A built-in one minute timer ensures that the motor magnetic field has collapsed before it injects DC power into the windings. When the motor is restarted, the MWH Series instantly turns off. No operator interface is required… the MWH Series is in control.

 

Built-in Overload Sensing

The MWH Series had an optional shutdown input that can be connected to the N.O. auxiliary contact on the motor starter’s thermal overload relay. This will disable the motor winding heater control, preventing any additional heating in the motor and allowing for a faster motor cool down period. The MWH Series then goes back on-line after the overload relay is reset.

Ideal Alternative to Strip Heaters

Eliminate the cost and hassle of installing strip heaters into your motors. Simply wire up the MWH Series to generate heat throughout
the motor stator windings. The heat is dissipated evenly without the “hot spots” caused by strip heaters. Conduction of heat to the rotor, bearings and shaft is also more
effective which means maximized protection for the whole motor.

Motor Winding Heater Controls Brochure

RX Motor Protection Relay

AC Input Voltage
200 to 15 kV

Current Rating
5 to 2000 A

Take your motor protection to a new level. The RX Series provides more than just solid state overload or power protection relays. By using features previously found only in large expensive Motor Protection Relays, the RX Series allows even small to medium sized motor applications to be protected by the best technology available, yet at a price affordable to all.

RX Motor Protection Brochure

TE-RTD12 Motor RTD Monitor / Relay Device

12 built-in RTD Inputs

2 Isolated Digital Inputs (4-20mA)

3 Programmable Form-C Output Relays

2 Isolated Analog Inputs (4-20mA)

Differential Current Feedback Monitoring

RS485 MODBUS-RTU Communication

The TE-RTD12 Relay device adds advanced RTD (Resistor Temperature Detector) and differential current monitoring capability to your new or existing motor system. The TE-RTD12 Relay device offers 12 built-in RTD inputs, 3 programmable output relays (5A), 2 isolated analog inputs (4-20mA), 1 isolated analog output (4-20mA), 3 isolated digital inputs, and differential current feedback monitoring.

TE-RTD12 Brochure

Current Transformers 

600V Non-Ansi Rated Window Type

Voltage: 600 Non-Ansi Rated Window Type

Application: Ammeters, wattmeters, and cross compensation.

Frequency: 50-400 Hz

Insulation Level: 600 Volts, 10 kV BIL full wave

Current Transformers Brochure

Medium Voltage Transformers

Indoor Voltage Transformers

PTG3-1-60 & PTG3-2-60

Accuracy Class: 0.3 WXMY, 0.6M, 1.2Z at 100% rated voltage with 120V based ANSI burden. 0.3 WX, 0.6M, 1.2Y at 58% rated voltage with 69.3V based ANSI burden

PTW3-1-60 & PTW3-2-60

Accuracy Class: 0.3 WXMY, 1.2Z at 100% rated voltage with 120V based ANSI  burden. 0.6 WX, 1.2MY at 58% rated voltage with 69.3V based ANSI burden.

Medium Voltage Transformers Brochure